| CZ-PO-CPS-C-Shutdown | |
| Data collected on: 2-9-2025 09:30:49 | |
| Domain | emea.tpg.ads |
| Owner | S-1-5-21-513466819-3096973226-347852806-532605 |
| Created | 16-8-2019 13:55:10 |
| Modified | 15-5-2023 10:23:28 |
| User Revisions | 0 (AD), 0 (SYSVOL) |
| Computer Revisions | 63 (AD), 63 (SYSVOL) |
| Unique ID | {3fc76a04-2315-40c1-8390-60a93f5c10f0} |
| GPO Status | Enabled |
| Location | Enforced | Link Status | Path |
|---|---|---|---|
| Production | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/BRQ/Production |
| Staff | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/BRQ/Staff |
| Production | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/HOD/Production |
| Staff | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/HOD/Staff |
| Production | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/PRB/Production |
| Staff | No | Enabled | emea.tpg.ads/CZ/Systems/Clients/PRB/Staff |
| Name |
|---|
| EMEA\CZ-L-SEC-ComputerShutDown3am |
| WMI Filter Name | Do not apply GPO where name like LT |
| Description | None |
| Name | Allowed Permissions | Inherited |
|---|---|---|
| EMEA\CZ-G-ORG-OU Admins | Edit settings, delete, modify security | No |
| EMEA\CZ-L-SEC-ComputerShutDown3am | Read (from Security Filtering) | No |
| EMEA\Domain Admins | Edit settings, delete, modify security | No |
| NT AUTHORITY\Authenticated Users | Read | No |
| NT AUTHORITY\ENTERPRISE DOMAIN CONTROLLERS | Read | No |
| NT AUTHORITY\SYSTEM | Edit settings, delete, modify security | No |
| ROOT\Enterprise Admins | Edit settings, delete, modify security | No |
| S-1-5-21-513466819-3096973226-347852806-532605 | Edit settings, delete, modify security | No |
| Policy | Setting | Comment |
|---|---|---|
| Control Event Log behavior when the log file reaches its maximum size | Disabled |
| Policy | Setting | Comment |
|---|---|---|
| Control Event Log behavior when the log file reaches its maximum size | Disabled |
| Policy | Setting | Comment |
|---|---|---|
| Control Event Log behavior when the log file reaches its maximum size | Disabled |
| Policy | Setting | Comment |
|---|---|---|
| Control Event Log behavior when the log file reaches its maximum size | Disabled |
| Action | Replace |
| Source file(s) | \\czprgfs01.emea.tpg.ads\cz\Public\Domain\Scripts\*.* |
| Destination folder | c:\scripts |
| Suppress errors on individual file actions | Disabled |
| Read-only | Disabled |
| Hidden | Disabled |
| Archive | Enabled |
| Stop processing items on this extension if an error occurs on this item | No |
| Remove this item when it is no longer applied | No |
| Apply once and do not reapply | No |
| Action | Update |
| Name | Shutdown | |||
| Author | EMEA\gerhart.10-adm | |||
| Description | ||||
| Run only when user is logged on | S4U | |||
| UserId | NT AUTHORITY\System | |||
| Run with highest privileges | HighestAvailable | |||
| Hidden | No | |||
| Configure for | 1.3 | |||
| Enabled | Yes |
| 1. Daily | ||||
| Activate | 16-8-2019 03:00:00 | Synchronize across time zones | No | |
| Enabled | Yes | |||
| Recur every 1 days |
| 1. Start a program | ||||
| Program/script | c:\scripts\shutdown.bat | |||
| Start in | c:\windows\system32 |
| Stop if the computer ceases to be idle | Yes | |||
| Restart if the idle state resumes | No | |||
| Start the task only if the computer is on AC power | Yes | |||
| Stop if the computer switches to battery power | No | |||
| Wake the computer to run this task | Yes | |||
| Allow task to be run on demand | Yes | |||
| Stop task if it runs longer than | 1 hour | |||
| If the running task does not end when requested, force it to stop | Yes | |||
| If the task is already running, then the following rule applies | StopExisting |
| Stop processing items on this extension if an error occurs on this item | No |
| Remove this item when it is no longer applied | No |
| Apply once and do not reapply | No |